Quick answer: Plan on 20 to 30 BTU per square foot for cooling and 32.5 to 55 BTU per square foot for heating, depending on your state's climate. A 1,500 sq ft home needs about 30,000 BTU of cooling in a cold northern state and 45,000 in a hot southern one. That is 2.5 tons and 4 tons of central AC.
BTU per square foot by climate zone
Every state falls into one of five climate zones. The zone sets the starting figure; your home's details adjust it from there.
| Zone | Typical area | Cooling, BTU/sq ft | Heating, BTU/sq ft | Open the calculator |
|---|---|---|---|---|
| Zone 1 (Hot) | Florida, Hawaii, far south Texas | 30 | 32.5 | BTU for Zone 1 |
| Zone 2 (Warm) | Texas, Arizona, Gulf states | 27.5 | 37.5 | BTU for Zone 2 |
| Zone 3 (Mild) | California, the Carolinas, Tennessee | 25 | 42.5 | BTU for Zone 3 |
| Zone 4 (Cool) | Mid-Atlantic, Midwest south, Pacific NW | 22.5 | 47.5 | BTU for Zone 4 |
| Zone 5 (Cold) | New England, upper Midwest, Mountain north | 20 | 55 | BTU for Zone 5 |
BTU per square foot for every state
Average insulation and 8-foot ceilings. AC sizes are the nearest standard central AC size; heating is the heat output a 2,000 sq ft home needs.
| State | Zone | Cooling, BTU/sq ft | Heating, BTU/sq ft | AC for 1,500 sq ft | AC for 2,000 sq ft | Heat for 2,000 sq ft, BTU |
|---|---|---|---|---|---|---|
| Alabama | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Alaska | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Arizona | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Arkansas | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| California | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| Colorado | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Connecticut | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Delaware | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| District of Columbia | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Florida | 1 | 30 | 32.5 | 4 ton | 5 ton | 65,000 |
| Georgia | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Hawaii | 1 | 30 | 32.5 | 4 ton | 5 ton | 65,000 |
| Idaho | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Illinois | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Indiana | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Iowa | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Kansas | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Kentucky | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Louisiana | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Maine | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Maryland | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Massachusetts | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Michigan | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Minnesota | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Mississippi | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Missouri | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Montana | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Nebraska | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Nevada | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| New Hampshire | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| New Jersey | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| New Mexico | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| New York | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| North Carolina | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| North Dakota | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Ohio | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Oklahoma | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| Oregon | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Pennsylvania | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Puerto Rico | 1 | 30 | 32.5 | 4 ton | 5 ton | 65,000 |
| Rhode Island | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| South Carolina | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| South Dakota | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Tennessee | 3 | 25 | 42.5 | 3 ton | 4 ton | 85,000 |
| Texas | 2 | 27.5 | 37.5 | 3.5 ton | 5 ton | 75,000 |
| Utah | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Vermont | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Virginia | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Washington | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| West Virginia | 4 | 22.5 | 47.5 | 3 ton | 4 ton | 95,000 |
| Wisconsin | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
| Wyoming | 5 | 20 | 55 | 2.5 ton | 3.5 ton | 110,000 |
No state matches that name.
How to use these numbers
- Find your figure
Look up your state. For a 1,800 sq ft home in Ohio (Zone 4) that is 22.5 BTU per sq ft for cooling and 47.5 for heating.
- Multiply by your area
1,800 × 22.5 = 40,500 BTU of cooling, and 1,800 × 47.5 = 85,500 BTU of heating.
- Convert to equipment sizes
40,500 ÷ 12,000 = 3.38 tons, so a 3.5-ton central AC. See the tons to BTU converter for other sizes.
- Adjust for your home
Ceiling height, insulation, sun, a kitchen or more people all change the result. The AC size, furnace and heat pump calculators apply them for you. For a single room heated with a plug-in heater, use the space heater calculator.
The map at a glance
Tap or hover a state to see its cooling figure.
Climate zones by state
Tap or hover over a state to see its zone and BTU factor.
What changes BTU per square foot
- Ceiling height. The figures assume 8 feet. Multiply by your height divided by 8.
- Insulation. A drafty older home needs about 15% more; a tight, well-insulated one about 10% less.
- Sun. A very sunny room needs about 10% more cooling and a heavily shaded one about 10% less, the same adjustment ENERGY STAR used in its room AC chart.
- Kitchens and people. A kitchen adds about 4,000 BTU of cooling, and each regular occupant beyond two adds about 600.
- Local climate. Mountains, coasts and the far ends of large states can differ from the state figure. Pick the zone that matches your summers and winters.
Where these numbers come from
The five zone figures are our own rule of thumb, set close to the ENERGY STAR room air conditioner chart in mild climates and adjusted up or down for hotter and colder states. Each state is placed in the zone that covers most of its population. The full method, including how ZIP codes are matched to zones, is on the how we calculate page. A rule of thumb is a planning figure: before you buy central equipment, ask a contractor for a Manual J load calculation.