Quick answer: Add up the running watts of everything you want on at once, then add the extra surge of the one motor with the biggest start. The essentials (refrigerator, sump pump, furnace blower, lights, TV and laptop) need about 2,820 running and 3,640 starting watts with 10% headroom, so a 3,500 W portable generator covers them. Add a 3-ton central AC and you need about 6,710 running and 8,540 starting watts.
Generator size for common outage setups
Each row is run through the calculator above. "Need" includes the 10% headroom on running watts. The example size is the smallest running / starting rating in Briggs & Stratton's portable lineup that covers it, with 240 V output where a load needs it.
| What you power | Running | Peak at start | Need | Example size |
|---|---|---|---|---|
| Essentials: fridge, 1/2 HP sump pump, furnace blower, 10 LED bulbs, TV, laptop | 2,532 W | 3,632 W | 2,820 / 3,640 W | 3,500 / 4,375 W |
| Essentials + microwave and coffee maker | 4,632 W | 5,732 W | 5,150 / 5,740 W | 5,750 / 7,185 W |
| Essentials + 1/2 HP well pump | 4,032 W | 6,282 W | 4,480 / 6,290 W | 5,000 / 6,500 W |
| Essentials + one window AC | 4,032 W | 5,132 W | 4,480 / 5,140 W | 5,000 / 6,500 W |
| Essentials + 3-ton central AC | 6,032 W | 8,532 W | 6,710 / 8,540 W | 7,000 / 8,750 W |
| Essentials + electric water heater | 7,032 W | 8,132 W | 7,820 / 8,140 W | 8,000 / 10,000 W |
Generator size for central air
Central AC watts by size, scaled from Champion's 3-ton figure, and the generator you need to run it with the essentials. These are typical figures; the starting surge of a real unit can be much higher, which is why the calculator takes the nameplate LRA.
| AC size | AC running | AC starting | With essentials, need | Example size |
|---|---|---|---|---|
| 1.5 tons | 1,750 W | 3,000 W | 4,760 / 5,540 W | 5,000 / 6,500 W |
| 2 tons | 2,333 W | 4,000 W | 5,410 / 6,540 W | 5,750 / 7,185 W |
| 2.5 tons | 2,917 W | 5,000 W | 6,060 / 7,540 W | 7,000 / 8,750 W |
| 3 tons | 3,500 W | 6,000 W | 6,710 / 8,540 W | 7,000 / 8,750 W |
| 3.5 tons | 4,083 W | 7,000 W | 7,350 / 9,540 W | 8,000 / 10,000 W |
| 4 tons | 4,667 W | 8,000 W | 8,000 / 10,540 W | Home standby |
| 5 tons | 5,833 W | 10,000 W | 9,300 / 12,540 W | Home standby |
Need is running / starting watts. Not sure what size your AC is? The tonnage is usually in the model number on the outdoor unit; see AC tonnage by square footage.
Appliance wattage chart
The wattages the calculator uses. Starting watts are the total an appliance draws for the second or two it takes to start, so a microwave or heater shows the same figure in both columns.
| Appliance | Running | Starting | Source |
|---|---|---|---|
| Refrigerator or freezer | 192 W | 1,200 W | Honda |
| Sump pump, 1/3 HP | 800 W | 1,300 W | Honda |
| Sump pump, 1/2 HP | 1,050 W | 2,150 W | Honda |
| Well pump, 1/2 HP submersible | 1,500 W | 3,750 W | Generac |
| Well pump, 1 HP submersible | 2,000 W | 5,000 W | Generac |
| Furnace blower, 1/3 HP | 700 W | 1,400 W | Honda |
| Furnace blower, 1/2 HP | 875 W | 2,350 W | Honda |
| LED bulbs, per bulb | 15 W | 15 W | Champion |
| Flat-screen TV, 46 in. | 190 W | 190 W | Honda |
| Laptop | 250 W | 250 W | Honda |
| Window AC, 10,000 BTU | 1,500 W | 2,200 W | Honda |
| Space heater | 1,500 W | 1,500 W | Champion |
| Microwave, 1,000 W | 1,500 W | 1,500 W | Honda |
| Coffee maker | 600 W | 600 W | Honda |
| Dishwasher, cool dry | 216 W | 540 W | Honda |
| Washing machine | 1,200 W | 1,200 W | Honda |
| Electric range, one 8 in. element (240 V) | 2,100 W | 2,100 W | Honda |
| Electric clothes dryer (240 V) | 5,400 W | 6,750 W | Honda |
| Electric water heater (240 V) | 4,500 W | 4,500 W | Honda |
| Garage door opener | 720 W | 1,420 W | Honda |
Honda: wattage estimation guide. Champion: upper end of its published ranges (LED bulbs; space heater at 1,500 W, the same as our space heater calculator). Generac: 9600 owner's manual, running watts × 2.5 to start. Your appliance's nameplate is the final word.
Portable or home standby?
Champion groups generators by running watts:
- 1,000 to 3,000 W: lights and small appliances.
- 3,000 to 7,000 W: refrigerator, freezer, window AC and TV.
- 7,000 to 12,500 W: central AC, electric water heater, well pump and sump pump.
- 12,500 to 22,000 W: whole-home coverage.
The largest portable in the Briggs & Stratton lineup the calculator uses is rated 8,000 running and 10,000 starting watts, though Champion lists portables of 22,000 W and more. Portables run appliances on extension cords or feed the house through a transfer switch. If your result is larger, or you want the house to switch over on its own, look at a home standby generator. Generac's air-cooled standby units run from 10 to 28 kW, and it calls 22 kW the industry standard for a 2,000 sq ft home. Standby units run on natural gas or propane. On a dual-fuel portable, Champion says propane gives about 10% less output than gasoline and natural gas 10 to 15% less, so size up if you won't be burning gasoline.
Generator safety
- Run it outside, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents (CPSC).
- Never run it in a garage, basement, crawlspace, shed or on a porch, even with the doors open.
- Put battery or battery-backup CO alarms on every level and outside sleeping areas. Look for a generator with automatic CO shut-off.
- Never plug it into a wall outlet. Backfeeding can kill utility workers. Use a transfer switch installed by an electrician, or heavy-duty outdoor extension cords rated above the load on them.
Cut the size you need
The surge, not the running total, is often what pushes you into a bigger generator. The trace in the calculator starts the biggest motor last, the worst case. Start it first, while little else is on, and turn the rest on one at a time; keep the water heater, dryer and AC from running together. If your home has electric heat, a heat pump or gas furnace needs only a blower on the generator, where Home Depot lists an electric furnace at 5,000 to 25,000 W. For a single cold room during an outage, a 1,500 W heater on its own circuit is easier on a small generator than the central system.
How the calculator works
- Running watts
Each appliance's running watts × how many you have, added up. Figures come from Honda's, Champion's and Generac's published wattage charts.
- Central AC
Your size in tons × 1,167 W running and 2,000 W starting per ton, from Champion's 3-ton figures. If you enter the nameplate LRA, starting watts are LRA × 240 V instead.
- Peak
Only one motor starts at a time. The peak is all running watts plus the extra surge (starting minus running) of the motor with the biggest surge. Lowe's and Generac worksheets add that motor's full starting figure, which counts its running watts twice and gives a slightly larger number.
- Size
Running watts ÷ 0.9, so the generator runs at no more than 90% of capacity, and the peak for starting watts. The example size is the smallest Briggs & Stratton portable rating that meets both, with 240 V output if a load needs it.